GV-RK1352 and GV-R1352 Card Reader
The GV-RK1352 and GV-R1352 are card readers designed to recognize identifications cards.
GV-RK1352 comes with keypad, allowing it to also recognize PIN codes. Featured with the
Wiegand and RS-485 outputs, the readers can be connected to any standard access control
panel. The readers are protected by a weather sealed and IP66 compliant housing for
outdoor use.
The content of this installation guide refers to the following readers:
GV-RK1352 firmware V1.2
GV-R1352 firmware V1.2
Packing List
GV-RK1352
1. GV-RK1352 Card Reader
2. Screw x 2
3. Screw Anchor x 2
4. Front Cover Plate x 2
Front View
GV-R1352
February 6, 2015
1
1. GV-R1352 Card Reader
2. Screw x 3
3. Screw Anchor x 2
4. Security Torx
Front View
Zobrazit stránku 0
1 2 3 4 5 6 ... 20 21

Shrnutí obsahu

Strany 1 - Packing List

GV-RK1352 and GV-R1352 Card Reader The GV-RK1352 and GV-R1352 are card readers designed to recognize identifications cards. GV-RK1352 comes with keyp

Strany 2 - 1. Physical Descriptions

2. Select the COM port that is connected to the reader and click Open COM. The serianumber and firmware version of the reader will be automatically

Strany 3 - 1.2 Keypad (GV-RK1352 Only)

4.2 Adding the Reader to GV-System 1. In GV-System, click the Configure button, select Accessories, and select GV Wiegand Capture Device Setting. T

Strany 4 - Wiegand A

5. Changing the Default Settings of Beeper and LED You can change the default settings of the LED and the beeper by enabling a GV-AS210 / d LED, g

Strany 5

2. Click Open COM. The serial number and the firmware version of the reader will be automatically detected. 3. To enable external control o

Strany 6

5.2 Wiring the Beeper and LED to the GV-AS Controller To wire the beeper and LED to GV-AS210 / 2110 / 400 / 410 / 4110 / 810 / 8110, connect the co

Strany 7

After wiring, you also need to go to GV-ASManager to select the alarm conditions that will set the device list, off the reader’s beeper. In GV-ASMan

Strany 8

5.3 Configuring the Beeper and LED Settings for Each Door/Gate After connecting the wires for beeper or LED, specify the conditions to trigger the

Strany 9 - (Blue) RS-485 +

6. Setting UID or GID on GV-R/RK/DFR Config AP By default, the readers read the UID (unique identifier) on ID cards or key fobs. Using GV-R/RK/DFR C

Strany 10

To use GID, make sure there are two numbers on your GV-AS ID Cards / Key Fobs as shown below. If there is only one number on your GV-AS ID Cards /

Strany 11

7. Firmware Upgrade included in the Software CD. Important Notes before You Start Before you start updating the firmware, please read these impo

Strany 12 - -R/RK/DFR Config AP

1. Physical Descriptions 1.1 Electric Wire GV-RK1352 Wire Color Function Red DC 7.5 ~ 12 V Black GND Yellow Beeper Orange Green LED Light Red

Strany 13

8. Specifications GV-RK1352 GV-R1352 CPU 8-bit microprocessor Frequency 13.56 MMifare CHz for ISO14443A (Mifare DESFire, Mifare Plus and lass)

Strany 14

February 6, 2015 21RK1352 Only) O tional accessories can exp bilities and versatilit V-RK1352 Card Reader. Consult your sales r information. 9. Ac

Strany 15

1.2 Keypad (GV-RK1352 Only) When accessing an entry using GV-RK1352, you can enter the door’s PIN code on the keypad or present the card and then en

Strany 16

2. Connecting the Reader to GV-AS Controller You can connect the readers to GV-AS Controllers through Wiegand or RS-485 interface. Note that the co

Strany 17

2.2 Connecting through RS-485 Interface The following diagrams use GV-RK1352 and GV-AS810 Controller as an example. Up to eight readers can be conne

Strany 18

2.2.1 Defining Readers on GV-AS Controller Web Interface Since multiple readers can connect to GV-AS Controller using one RS-485 interface, you nee

Strany 19 - 7. Firmware Upgrade

4. Next to Read Mode, select Read UID or Read GID to set the connected readers to read UID (unique identifier) or GID (GeoVision ID) on GV-AS ID Card

Strany 20 - 8. Specifications

3. Installing the GV-R/RK/DFR Config AP Th master / slave status, and whether it reads UID or GID. When using the Config AP, the reader needs to b

Strany 21 - 9. Accessory (GV

4. Overlaying Card Numbers on GV-System Live View You can overlay card numbers recognized at the reader onto a camera channel on GV-System. To overl

Komentáře k této Příručce